Transformation of the turbogenerator block diagram-2

14.2

Fig. 6 shows the transformation of the block diagram of

the turbogenerator in the section ΔUa*/ΔEfd*. Therefore, we

are interested in the behavior of the regulation system when acted

upon by the excitation system, assuming Mмх = const. The

transfer functions Gг1(p) and Gг2(p) are determined using using

the method of Logarithmic Amplitude-Frequency

Characteristics (LAFC) (see Fig. 7, page 14.6).

G3.2(p) = 
Δδ1
ΔEfd*
 = 
G2
1 + G2·H2
 
When G2

>

1
H2
:

G3.2

=
1
H2
When  G2

<

1
H2
 

G3.2

=

G2  
G2=   
K2·K3·ωн·1/D
(1 + p·T′do·K3(1 +p·T1)
 · 
1
p

 =

  =

1.29·0.26·1/2·314

(1 +p·9.3·0.26)(1+p5)

·

1
p

=

 
52.6
(1 + p·2.4)(1 +p·5)
· 
1
p

at

   p=1,   K

=

 
52.6
2.4·5
 =4.34
 
1
H2
 = 
1
K4
 = 
1
1.68
 = 0.58

From plots:

G3.2

=

0.58

·

1

(1 + p·0.55)3

G3.3

=
G3
1 + G3·H3
  G3=1

H3

=

314·0.85·1/2
(1 + p·5)
 · 
1
p
 = 
133.5
1 + p·5

·

1
p
1
H3
 = 
p(1 + p·5)
133.5

 G3.4 

=

1
1 + G4·H4
           G4=1
H4

=

ωн·K2·K3·K4
D
·
1
p

·

1
1 +p·T1
·
1
1+ p·T′do·K3

=

= 

 
314·1.29·0.26·1.68
2
 · 
1
p
 · 
1
1 + p·5
 · 
1
1 + p·2.4